Diagnostic ASSR & SSEP
Grason-Stadler and Audioscan products not available in all areas. Contact you Trilogy Audiometrics dealer for more information.
Bio-logic Systems Corp. M·A·S·T·E·R II
![]() | New & Improved Software Version • Updated user interface • Two channel option • Patient database shared with other Bio-logic applications • Expanded automated data collection stopping rules • Enhanced patient reports M•A•S•T•E•R II is a must have addition to the clinical electrophysiological test battery especially when testing patients for whom behavioral audiometry may be unreliable, such as: • Infants and young children • Children or adults with special needs • Workers’ compensation cases |
ICS Medical Chartr EP 200
![]() | ICS Chartr EP 200 is a new system for Auditory Evoked Potential testing. The system builds on the expertise of our acknowledged ICS Chartr line, creating a portable, easy-to-use system. The patient database includes data from EP, ASSR and VNG/ENG tests. Pediatric friendly hardware The ICS Chartr EP 200 hardware was built with the Pediatric population in mind. The system comes with a preamp shoulder harness and a lanyard that make it possible to hang or attach the preamp to the patient’s crib or to rest it over the guardian’s shoulder. Impedance values are displayed on the preamp, allowing you to stay close to the patient and verify the connectivity of the electrodes. A comprehensive remote control lets you maintain that personal contact needed during Pediatric testing. |
Interacoustics ASSR
| Interacoustics ASSR - Diagnostic ABR Software Description New Generation ASSR The new ASSR system from Interacoustics is not just another ASSR system. It incorporates years of research aimed at taking ASSR a grand step further: • Up to 50% faster • Full stimulus control • Powerful complete 2 channel system • NOAH compatible (v. 3.6 or later) Reduce Test Time by up to 50% Conventional ASSR systems use an algorithm detection method based in the phase domain or the frequency domain. The Full Spectrum Detection Engine built into the Interacoustics ASSR system combines both methods. It also uses information carried by the higher harmonics of the response to strengthen detection – typically reducing test time with 50%. Full Stimulus Control The Interacoustics ASSR system allows both ears to be tested at the same time. As a test progresses you can control stimulation intensity for each of the 4 simultaneous frequencies in each ear as well as controlling start and stop times for a particular stimulus. Powerful 2 Channel System Using two channels and running two detection engines in parallel allows the Interacoustics ASSR system to also obtain optimum results when used with traditional clinical ABR electrode montage. NOAH Compatible (v. 3.6 or later) If you run the Interacoustics ASSR system under NOAH the resulting Estimated Audiogram will be saved in the NOAH database making the results available for any Hearing Aid Fitting module running under NOAH. |




M·A·S·T·E·R II Brochure








